Short answer: This is the Florida Building Commission's official analysis of what changes between the 8th Edition (2023) and 9th Edition (2026) Florida Building Code, Existing Building. The 9th Edition takes effect statewide on December 31, 2026. We host the full document below and summarize the changes the Commission itself marked as most significant.
Read the document: Analysis of Changes for the 9th Edition (2026) Florida Building Code: Changes to the Florida Building Code, Existing Building (PDF, 11 pages). Official source: floridabuilding.org.
Key facts
- Document: Analysis of Changes for the 9th Edition (2026) Florida Building Code: Changes to the Florida Building Code, Existing Building
- Published by: Florida Building Commission (Florida Department of Business and Professional Regulation)
- Length: 11 pages (PDF)
- Covers: repairs, alterations, additions, changes of occupancy and reroofing on existing buildings
- Model code used for the update: 2024 International Existing Building Code, plus Florida-specific amendments
- Code effective date: December 31, 2026, for permit applications filed on or after that date
Changes the Commission marked most significant
The Commission highlights the changes it considers most significant or most impactful. These are the ones it highlighted in this volume.
| Section | What changes |
|---|---|
| 302.6.2 | Swimming pools keep Florida's single-wire equipotential bonding of perimeter surfaces instead of the NFPA 70 copper or steel grid. |
| 407.1 | Repairs to existing electrical wiring and equipment must comply with NFPA 70. The old allowance to repair or replace with like materials is deleted. |
| 503.2, 701.3 | Exterior equipment and appliances replaced after flood damage must be elevated to the first-floor height or 4 feet above grade, whichever is higher, unless the work is a substantial improvement. Dry floodproofed enclosures are allowed for nonresidential buildings. |
| 1012.2.1.1 | Nonrequired automatic sprinkler systems may be removed under set conditions, with plans and evaluation reports submitted for the code official's approval. |
Other changes worth knowing
- Reroofing (706.3): Exception 3 is revised so that, when recovering, only the upper roof covering or system has to come off if the remaining substrate is adequate. Exception 5 on roof coatings is replaced with language on existing vapor barriers and self-adhering underlayments.
- New sections 706.7.3.1 through 706.7.3.3 set which coverings may go over an existing self-adhering underlayment: shingles, metal, roll roofing, slate and wood; clay and concrete tile; and low-slope continuous systems.
- Window and door replacement (707.4) now points to the flashing requirements in the Building and Residential codes.
What it means for your project
For renovation, repair and reroofing work, the Existing Building volume decides how much of an older building has to be brought up to the new code, and it changes how flood-damaged equipment and electrical repairs are handled.
Which edition applies is set by the date your permit application is filed, not the review or issue date. Applications filed before December 31, 2026 stay under the 8th Edition for the life of the permit. Each jurisdiction sets its own cutoff, so file complete applications early and confirm locally.
Frequently asked questions
When does the 9th Edition Florida Building Code take effect?
December 31, 2026, statewide. Any building permit application first submitted on or after that date must comply with the 9th Edition. Applications filed before it stay under the 8th Edition (2023) for the life of the permit.
What changed for reroofing in the 9th Edition?
Section 706.3 Exception 3 now lets a roofer remove only the upper roof covering or system when recovering, as long as the existing or repaired substrate is adequate for the new roof. Separately, F.S. 553.844(5) still provides that when 25 percent or more of a roof built under the 2007 code or later is repaired, replaced or recovered, only that portion must meet the current code.
Do flood-damaged AC units have to be raised when replaced?
Under 503.2 and 701.3, exterior equipment and appliances replaced after flood damage must be elevated to the first-floor height or 4 feet above grade, whichever is higher, unless the replacement is part of a substantial improvement or repair of substantial damage.
Is my project governed by the date of permit application or permit issuance?
The date of application. Under Florida law, the edition in effect on the date a permit application is filed governs the work for the life of the permit. Each jurisdiction sets its own cutoff and its own definition of a complete application, so confirm locally.
The rest of the 9th Edition library
See the full 9th Edition Analysis of Changes library and our overview, The Florida Building Code 9th Edition Takes Effect December 31, 2026.
- 9th Edition Florida Building Code, Building: Analysis of Changes
- 9th Edition Florida Building Code, Residential: Analysis of Changes
- 9th Edition Florida Building Code, Energy Conservation (Residential): Analysis of Changes
- 9th Edition Florida Building Code, Energy Conservation (Commercial): Analysis of Changes
- 9th Edition Florida Building Code, Mechanical: Analysis of Changes
- 9th Edition Florida Building Code, Plumbing: Analysis of Changes
- 9th Edition Florida Building Code, Fuel Gas: Analysis of Changes
- 9th Edition Florida Energy Code: Significant Changes (DBPR Overview)
Sources: Analysis of Changes for the 9th Edition (2026) Florida Building Code: Changes to the Florida Building Code, Existing Building, Florida Building Commission (Florida Department of Business and Professional Regulation); Miami-Dade County 9th Edition notice. The Commission notes the analysis is not intended to replace or interpret the code; confirm requirements against the adopted 9th Edition at floridabuilding.org. This page is general information, not legal or engineering advice.